How Siphonic System Works?
The Siphonic System forms the desired low pressure by partially filling the pipes even in low rain. So that the landing pipe section is closed. At the same time, the system-tailored Teti Uds Siphonic Strainer prevents Airstop from entering the pipe system caused by “Coriolis Force”.
Due to the rainwater flowing through the down pipe with the drainage of the siphonic rainwater, a “suction-lifting effect” produces a low pressure in the collection pipe that quickly seizes the roof area or the pipeline system.
Filling the pipes with rainwater drainage and the pressure difference caused by the height difference leads to a high flow rate, thus providing advantages in terms of construction technique and yield.
Siphonic System Accessories
Siphonic system materials are collected at three main headings.
a) Special Drainage Drains with air traps.
b) Internal vacuum resistant pipes and fittings.
c) Suspension Elements
Teti UDS Siphonic System Drains:
In addition to its high flow performance, it is specially designed to reduce friction losses to a minimum; high capacity and suitable for the
conditions of the region can be used with its heating devices to suit for all climatic conditions, which can absorb the heat differences within and
is suitable for the type of insulation of the building.
Teti UDS Products
Teti UDS Siphonic Rain Drainage System includes pipes, siphon, fittings, supporting systems and is designed in TETI UDS software.